Little Shop of Coral
Brightwell Xport NO3 Plate 9" x 8" x 1.5"
Brightwell Xport NO3 Plate 9" x 8" x 1.5"
Couldn't load pickup availability
Xport NO3 Plate
Ultra-activated Denitrification Plate Media, doped with Elemental Sulfur for Superior Performance Characteristics
Overview
- Designed to be used in marine and hard freshwater aquariums with a pH of 7.5 or over
- Highest porosity and largest useable surface area, per unit weight or volume, of all filtration media available anywhere!
- Provides huge amounts of anaerobic surface area for efficient bacterial colonization for denitrification, along with sulfur doping to act as an electron donor to accelerate the process in freshwater, pond or marine applications.
- Laboratory Tested: Provides over 71,000 square feet (6,596 square meters) of surface area per liter of medium. One plate has about 125,000 square feet of useable surface area for bacterial colonization.
- Also reduces phosphate significantly and dissolved organics.
- So porous that it wicks water and stays wet for days when drained, allowing bacteria to remain viable after an equipment failure and ready for the repair.
- Doped with Aragonite to buffer pH at bacteria level, preventing acid buildup which eventually would kill the bacteria and reduce capacity (which is what happens in competing products).
Instructions Guidelines
Use one XPort NO3 Plate for every 1,250 U.S. gallons ( 4,750 L ) of system capacity, more for heavy bio loads. Normally do not use more than one plate per 100 gallons of tank capacity. Plates may be cut in half for smaller systems or cut any way you like. Rinse material well with aquarium water or purified tap water to remove any dust. For superior results, seed the material using only the specific bacteria product that you are using in the aquarium. If using MicrōBacter Start XLM, use one capful to seed (add balance of bacteria directly to the aquarium). If using FlorinBacter7, MicrōBacter7 or MicrōBacterCLEAN add full recommended dose. Place XPort NO3 Plate in a plastic container, filling it with aquarium water, and then adding the bacteria to that container. Allow to stand overnight and then add the seeded XPort NO3 Plate to your system. It is recommended that you use sponge, fine filter floss or other mechanical filtration ahead of XPort NO3 Plate to prevent clogging with organic material. For maximum results, also provide a good carbon source for growing bacteria, such as Brightwell® Katalyst bio pellets or liquid Reef BioFuel or Florin Axis, as appropriate for your aquarium, as directed on their label.
Recommendation: Do not use different bacteria products in an aquarium, particularly during startup! When an aquarium is new, the available nutrients for bacteria to consume are scarce and if the kind of bacteria you introduce requires organics, they will likely not be available and the two different bacterial cultures can fight each other. It is best to start out with MicrōBacter Start and cycle the tank, and then progress to MicrōBacterCLEAN at cycling completion. Then progress to MicrōBacter7 or FlorinBacter7at 4 to 6 months of age. This will provide the cleanest and fastest route to meet your goals and provide a beautiful and sustainable bacterial ecosystem. Particularly do not introduce foreign strains of bacteria such as "live sand", pre-cultured dry man made "live rock," etc. It is ok to use rocks from other aquariums that have already cycled and live rock purchased from stores. All forms of man made or natural live rock (except dry pre-cultured), aragonite and marco rock will work fine. If you introduce the wrong strains of bacteria, at the wrong time, you can slow down the whole process.
Additional information
It is prudent to use a whole plate even in smaller systems down to about 100 U.S. gallons. If the system is smaller than that, then use the Xport NO3 Cubes or Xport Bio Blocks instead or cut the plate in half with a hack saw or to any size you like. To cut the plate, we recommend that you wet it first and place it on a piece of wood so that it is full supported. If you hang it over an edge, it may break unevenly. For nitrification, or removal of ammonia and nitrite, employing the plate aerobically, or above the water line will provide maximum results. To do this, mount the plate in air, above the water level, and run a small stream of water through the plate. It is not necessary or desirable to run the whole flow of the main system pump through the plate. A flow of about 40 liters per hour is ideal. An adjustable flow control will allow you to adjust the water flow to only that which will flow through (and not around) the plate. On the other hand, removing nitrate is an anaerobic process and limiting oxygen to the plate as much as possible will maximize the nitrate removal. In this case, mount the plate beneath the water surface in the sump in a very low flow area, if possible. Never mount the plate where it is flat against a surface, always put a spacer between the plate and the flat bottom of a sump, so that at least 1/4 inch of water can easily flow under the plate. This will prevent hydrogen sulfide generation.
To use one plate for both aerobic nitrification and anaerobic denitrification, mount the plate below the water surface and provide medium flow around it. The bacteria growing in the top 1/4" of the surface of the plate will be aerobic and will use up all the oxygen so that the inside of the plate goes anoxic or anaerobic. Anaerobic denitrifying bacteria will then colonize the internal surfaces of the plate and you will get both nitrification on the surface and denitrification in the internal parts.
While the NO3 plate will perform both nitrification and denitrification, it is primarily designed for denitrification. If you are needing primarily nitrification (removal of ammonia & nitrite), you should purchase the BIO Plate.
One important criteria in marine systems is gas exchange. Xport is the best bacterial media in the world, but it is not good at gas exchange. Bio balls are the best for gas exchange, so any system will work better with a small stack of bio balls placed in the main flow (in air).

Collapsible content
LIGHT
LOW: Place coral at the bottom of the tank. Depending on the type, coral may need to be placed off sand and therefore mounted on a ceramic disc of piece of rock.
MEDIUM: Place coral at mid-range of the tank. Best placed/glued on top of a rock scape at mid-range height.
HIGH: Place coral from mid range to just below water level. SPS coral are shallow growing so they require and are able to tolerate intense light.
FLOW
LOW: Most soft coral do well with a small, gentle pulse. There are certain corals that can even be placed in areas of indirect flow, meaning places aside a rock structure or set into a entrance to a cave style space.
MEDIUM: Many LPS types of coral prefer medium pulse current. Most Euphyllia or corals that have more tissue structure connected to their skeleton, don’t like to be in a high flow area like the direct flow of the wave pump.
HIGH: Similar to high light, SPS enjoy being in some heavy current. Most LPS and SPS that branch encrust or plate prefer high flow that simulates the top water waves.
SKILL
ENTRY: While some may say beginner level, "Entry" is a good term to be used when starting out in the world of corals and marine life. Prior to adding livestock, you want to ensure that your reef has the proper parameters including zero levels of ammonia and nitrite. Seeing traces of nitrate in your waters is a good sign - just keep them at a lower level of 2ppm to 10ppm. Maintaining correct temperature and salinity are a huge factor to stable parameters. Starting to monitor your PH, alkalinity, calcium and magnesium is a great habit to get into to keep a successful reef.
While some soft coral don’t require too much light, having a proper reef light that puts out the proper pars is very important. You'll also want to have a good amount of flow and protected rock areas, as placing corals in their happy spot is ideal for success.
ADVANCED: